    What factors should be considered for passive isolation of precision instruments?

    The stiffness of the supporting structure of the equipment, the overall contour size of the equipment, the interval between installing vibration dampers, and whether the center of gravity of the equipment is too high.

  • ask

    The customer feels that the noise from the rooftop equipment is obvious. How to determine whether it is a vibration or noise problem?

    In a noisy room, feel it with your ears against the wall, open and close the windows, observe if there are any changes in the indoor noise, and check if there are any sound leaks in the pipes or other areas of the room.

  • ask

    The vibration isolation of air conditioning units needs to be considered systematically, so where do vibration dampers need to be installed?

    Only considering the air conditioning unit and ignoring the vibration isolation of the water pump and pipeline will continue to generate vibration transmission, so comprehensive vibration isolation is necessary. Air conditioning units, pipe supports, rigid connections through walls, small motors, fans, and water pumps all require vibration isolation treatment.

  • ask

    What is the reason why the vibration reduction effect of rooftop air conditioning equipment installation is not obvious?

    Use your hands to touch the bottom corners of each device and the channel steel or ground below the shock absorber to see if the vibration is reduced. If there is a vibration short circuit, adjust the shock absorber. Check whether vibration reduction measures have been taken for the support of the water pump and pipeline through the wall, the strength of the floor structure, and whether the equipment is located at the load-bearing beam position.

  • ask

    How to operate the salt spray test for steel wire rope shock absorbers?

    Standard 304, neutral salt spray is generally between 48-72 hours; Standard 316, neutral salt spray generally lasts for 72 to 120 hours. The salt spray test is also related to the processing accuracy and surface flatness of the product.

One on one service provided by the technical team

Dedicated personnel provide specialized services to solve vibration problems

Provide vibration isolation calculation sheet

  • Determine the vibration situation of the equipment and identify the vibration source
  • Vibration reduction technicians develop vibration isolation plans and make precise selections
  • Provide 3D product drawings to support vibration isolation design during the product development phase
  • Guide installation to ensure high isolation efficiency
View details

Selection

I don't know how to solve the low-frequency vibration problem of the equipment. Contact the vibration reduction engineer: 183019993716

Customization

Customize vibration reduction products according to customer needs